Solutions / Data centers

Power distribution for facilities that cannot go dark

A data centre electrical room is a chain of dependencies: utility feeder, MV ring, transformer, LV main, UPS and PDU. SAGE Power supplies the MV and LV distribution layer in that chain as one coordinated, factory-tested scope, so protection settings, interlocking and interfaces are resolved before the equipment reaches site.

10–15 kV

MV incoming

1000–2500 kVA

dry-type transformer

2500–4000 A

LV busbar

Tier III / IV

topologies supported

Design priorities

What the electrical room has to get right

01

Dual-source MV architecture

Two independent 10 kV or 15 kV incomers with a mechanically interlocked bus tie, arranged for open or closed transition to match your topology.

02

Indoor dry-type transformation

SCB cast-resin transformers at 10 kV/0.4 kV, 1000–2500 kVA, AN/AF cooled, chosen for low loss and low partial discharge inside the building envelope.

03

Selective LV protection

Drawout LV switchgear with 2500–4000 A busbars, form 3b/4 segregation and interchangeable modules for fast fault isolation and maintenance.

04

Metering and integration

Multifunction meters, digital relays and RS485/Modbus interfaces ready for EPMS, BMS and SCADA integration.

Data Center power distribution solution - SAGE Power

Typical configuration

What a typical scheme looks like

A representative 10 kV supply for a Tier III-style facility; final values follow your single-line diagram, fault level and redundancy class.

  • MV incoming: 10 kV or 15 kV, 630–1250 A, 25 kA / 3 s
  • MV switching: ring main unit or KYN28-12 metal-clad, 2 incomers + bus tie
  • Transformer: SCB 10 kV / 0.4 kV, 1000–2500 kVA, dry-type, IP20–IP31
  • LV main: 400 V, 2500–4000 A, drawout, form 3b / form 4
  • Protection: numerical relays, key and mechanical interlocking, EPMS-ready metering
  • Enclosure: indoor, front access, cable entry from below or above

Recommended equipment

Equipment we would put in this scheme

KYN28 12kV metal clad medium voltage switchgear cabinet - SAGE Power

KYN28-12 switchgear

12 kV metal-clad withdrawable switchgear with four compartments and mechanical interlocking.

SCB series 10kV resin insulated dry type transformer - SAGE Power

SCB cast-resin transformer

10 kV class dry-type transformer, 50–5000 kVA, vacuum-cast windings, IP20–IP54 enclosures.

GGD 400V low voltage power distribution cabinet - SAGE Power

LV drawout switchgear

GCS and MNS-style drawout cabinets for 400 V main and distribution boards, form 3b/4.

YBM series 12kV prefabricated compact substation - SAGE Power

Intelligent compact substation

Prefabricated MV/LV substation with SCADA, pre-wired and routine tested for fast installation.

How we deliver

One team from drawing review to commissioning

01

Engineering review

We start from your single-line diagram, load list and fault level, then confirm the topology, ratings and protection scheme before anything is quoted.

02

Manufacture and test

Switchgear, transformers and substations are built in Yueqing, routine tested and documented against the relevant IEC and GB standards.

03

Delivery and support

Export packing, drawings, test reports and O&M manuals travel with the shipment, with commissioning support available on site.

Questions buyers ask

Frequently asked questions

Dry-type or oil-immersed transformer inside a data centre?

Dry-type: cast-resin transformers remove the oil fire load and are suitable for indoor electrical rooms, with low partial discharge and IP20–IP31 enclosures.

How is redundancy handled?

Two independent incomers feed a mechanically interlocked bus tie. The arrangement is set for open or closed transition to suit your Tier class and upstream protection.

Can you work to our single-line diagram?

Yes. Send the SLD, load list and fault level; we return a marked-up configuration, a bill of materials and a drawing set for approval.

How does the equipment integrate with EPMS or BMS?

Multifunction meters and protection relays expose RS485/Modbus data, and relay interfaces are documented for your BMS or EPMS integrator.

Chasing a Tier III or IV electrical room?

Send your single-line diagram, redundancy class and fault level. We will return a coordinated MV/LV configuration and a drawing set for review.