Overview
The GGD low voltage power distribution cabinet is a fixed electrical cabinet designed for power distribution, control and protection in low voltage power systems. It is commonly used in factories, commercial buildings, substations, infrastructure projects and industrial power distribution applications.
The cabinet features a steel enclosure and a practical internal arrangement for electrical components, control devices and busbar connections. The configuration can be customized according to the project requirements, including incoming and outgoing circuits, rated current, circuit breakers, meters, control components and cabinet dimensions.
The GGD cabinet can be supplied as part of a complete power distribution solution according to the customer’s electrical design.
Key Features
- Fixed cabinet structure — a fixed arrangement of components inside the enclosure.
- Steel enclosure — a sheet steel cabinet body for indoor low voltage distribution.
- Rated voltage 380V or 400V — suitable for standard low voltage distribution systems.
- Rated current up to 2500A — the cabinet is rated for main busbar currents up to 2500 A.
- Flexible incoming and outgoing circuit configuration — the number and arrangement of incoming and outgoing circuits can be set to suit the project.
- Customized electrical component arrangement — circuit breakers, meters and control components are selected and laid out to the agreed specification.
- Suitable for indoor power distribution systems — designed for installation inside a substation or distribution room.
- Factory assembly and inspection before shipment — each cabinet is assembled and inspected according to the agreed technical requirements before delivery.
Technical Specifications
| Model | GGD |
|---|---|
| Product type | Fixed low voltage power distribution cabinet |
| Rated voltage | 380V or 400V |
| Rated current | Up to 2500A |
| Cabinet structure | Fixed cabinet structure |
| Enclosure | Steel enclosure |
| Incoming and outgoing circuits | Flexible configuration, set according to the project requirements |
| Internal arrangement | Customized electrical component arrangement — circuit breakers, meters, control components and busbar connections |
| Cabinet dimensions | Customized according to the project requirements |
| Installation | Suitable for indoor power distribution systems |
| Quality control | Factory assembly and inspection before shipment; product photos, technical documents and inspection information can be provided according to project requirements |
Applications
- Industrial plants — main and sub-distribution in factory low voltage systems.
- Commercial buildings — power distribution and control for building services.
- Power distribution stations — indoor distribution cabinets in substations.
- Infrastructure projects — low voltage distribution as part of wider electrical works.
- Industrial power distribution — supplied as part of a complete power distribution solution according to the customer’s electrical design.
Installation Conditions
- The cabinet is intended for indoor power distribution systems, installed in a substation or distribution room.
- The cabinet is a fixed design, so components are mounted in a fixed arrangement and busbar connections are made inside the enclosure.
- Cabinet dimensions, incoming and outgoing circuit arrangement and the component list are agreed before production, so the foundation and cable entry can be prepared to the confirmed drawing.
- Each cabinet is assembled and inspected according to the agreed technical requirements before delivery.
How to Select
- Rated voltage — 380V or 400V — and the rated current required, up to 2500A.
- The single line diagram of the project.
- The number of incoming and outgoing feeders and their rated currents.
- The circuit breakers, meters and control components to be fitted.
- Cabinet dimensions and the arrangement of the outgoing circuits.
- The technical requirements and inspection information needed for the project record.
FAQ
What is the rated voltage and current of the GGD cabinet?
The rated voltage is 380V or 400V and the rated current goes up to 2500A.
Can the incoming and outgoing circuits be configured to my project?
Yes. The cabinet has a flexible incoming and outgoing circuit configuration, and the configuration can be customized according to the project requirements.
Which components can be fitted inside the cabinet?
The internal arrangement is customized and can include circuit breakers, meters, control components and busbar connections, laid out to suit the project requirements.
Where can the GGD cabinet be installed?
It is designed for indoor power distribution systems and is commonly used in industrial plants, commercial buildings, power distribution stations and infrastructure projects.
How is the cabinet inspected before delivery?
Each cabinet is assembled and inspected according to the agreed technical requirements before delivery. Product photos, technical documents and inspection information can be provided according to project requirements.
What information is needed to specify a GGD cabinet?
The single line diagram, the rated voltage, the rated current, the number of incoming and outgoing feeders and other technical requirements, so the suitable cabinet configuration can be confirmed before production.
Request Quote
Tell us your specifications, quantity, or application scenario and we will reply with a tailored quote.